Details
-
Bug
-
Status: Closed
-
Major
-
Resolution: Fixed
-
None
-
None
Description
Daniele:
I change the connectivity range with the sliding bar (for example for selecting the connectivity range from 0 to 0.16 instead of 0.2) and then run the simulation, the values are mysteriously extended back to the original range, including extra high values.
Lia:
What it worked for me was to select Step = 0.02 Range Start = 0.04 and End = 0.14
Could you, before trying this set of parameters execute a Browser -> Clean cache action?
Daniele:
It could indeed be a cache problem. actually what I was about to write you is that I did a TVBclean and the thing worked fine the first time, and bad the second.